# AGRINOVO-EMF-200: Insertion Electromagnetic Flow Meter

Agrinovo technical datasheet, revision 1.2 (October 2026).
PDF version: https://agrinovo.io/datasheets/sensors/AGRINOVO-EMF-200_Datasheet.pdf

## 1. Overview

The AGRINOVO-EMF-200 is an insertion-type electromagnetic flow meter for large-diameter pipelines. The probe mounts through a ball valve saddle and inserts into the pipe flow, allowing installation and removal without stopping flow (hot-tap). It contains no moving parts, causes virtually no pressure drop, and is unaffected by fluid temperature, pressure, density, viscosity, or conductivity (above minimum). The transmitter displays instantaneous flow, velocity, and accumulated volume on a backlit LCD and communicates over RS-485 Modbus-RTU.

### Key Features

- Pipe sizes: DN100-DN3000
- Hot-tap install/removal under pressure
- Accuracy: ±1.5% (velocity ≥1 m/s)
- Bidirectional flow measurement
- RS-485 Modbus-RTU
- 4-20mA + frequency/pulse outputs
- Sensor IP68, Transmitter IP65
- 85-250VAC or 20-36VDC power

### Applications

- Large-diameter supply and return mains
- Aquaculture system manifolds and headers
- Municipal water distribution
- Irrigation trunk lines and irrigation canals

## 2. Specifications

### Measurement

| Parameter | Specification |
|:----------|:--------------|
| **Pipe Size** | DN100-DN3000 |
| **Velocity Range** | 0-1 to 0-10 m/s (full-scale 1-10 m/s, continuously adjustable) |
| **Accuracy** | ±1.5% of reading (velocity ≥1 m/s) |
| **Min. Fluid Conductivity** | ≥30 µS/cm |
| **Max. Fluid Temperature** | 60°C |
| **Max. Working Pressure** | 1.6 MPa |

### Probe and Transmitter

| Parameter | Specification |
|:----------|:--------------|
| **Electrode Materials** | Stainless 316L, Hastelloy C (HC) |
| **Measurement Tube Material** | ABS |
| **Sensor Protection** | IP68 |
| **Transmitter Protection** | IP65 |
| **Max. Signal Cable Length** | 50 m (sensor to transmitter) |

### Insertion Length

| Pipe Size | Probe Length |
|:----------|:------------|
| DN ≤200 | 630 mm |
| DN250-DN400 | 730 mm |
| DN401-DN1200 | 830 mm |
| DN1401-DN2000 | 1030 mm |

Insertion depth: DN ≤400 - insert to ½ DN; DN >400 - insert to ¼ DN.

### Electrical

| Parameter | Specification |
|:----------|:--------------|
| **Supply Voltage** | 85-250VAC (45-63Hz) or 20-36VDC |
| **Power Consumption** | <20W |
| **Operating Temperature** | -10 to 55°C (ambient) |
| **Storage Temperature** | -40 to 65°C |

## 3. Wiring

### Integral Type (24VDC)

| Terminal | Function |
|:---------|:---------|
| **LN+** | 24V Power+ |
| **LN-** | 24V Power- |
| **TRX+** | RS485-A (Data+) |
| **TRX-** | RS485-B (Data-) |
| **IOUT** | 4-20mA Current Output |
| **IVIN** | 2-wire 24V Input |
| **POUT** | Frequency / Pulse Output (bidirectional) |
| **COMM** | Common Ground (frequency, pulse, current) |
| **ALM1** | High Alarm Output |
| **ALM2** | Low Alarm Output |

### Integral Type (220VAC)

| Terminal | Function |
|:---------|:---------|
| **L / N** | 220V Power Input |
| **TXD** | RS485-A (Data+) |
| **RXD** | RS485-B (Data-) |
| **IOUT** | 4-20mA Current Output |
| **POUT** | Frequency / Pulse Output |
| **COMM** | Common Ground |
| **ALMH** | High Alarm Output |
| **ALML** | Low Alarm Output |

> All digital outputs (frequency, pulse, alarm) are opto-isolated. Max load: 36VDC, 250mA.

## 4. Communication Settings

| Parameter | Value |
|:----------|:------|
| **Protocol** | Modbus-RTU |
| **Physical Interface** | RS-485 |
| **Baud Rate** | 1200 / 2400 / 4800 / **9600** / 19200 bps |
| **Data Bits** | 8 |
| **Parity** | None (Odd or Even selectable) |
| **Stop Bits** | 1 |
| **Default Address** | 0x01 |
| **Max Devices per Bus** | 99 |
| **Bus Termination** | 120Ω at each end of the RS-485 bus |
| **Isolation** | 1000V electrical + ESD protection |

### Data Format

All 32-bit values span two consecutive registers. Values are big-endian IEEE-754 float32 or big-endian int32: the lower register address holds the high 16-bit word, the next register holds the low 16-bit word.

## 5. Register Map

All registers are read with **Function Code 0x04** (Read Input Registers).

| Address (Dec) | Address (Hex) | Type | Description |
|:--------------|:-------------|:-----|:------------|
| 4112-4113 | 0x1010-0x1011 | Float32 BE | Instantaneous flow rate |
| 4114-4115 | 0x1012-0x1013 | Float32 BE | Instantaneous velocity (m/s) |
| 4116-4117 | 0x1014-0x1015 | Float32 BE | Flow percentage (%) |
| 4118-4119 | 0x1016-0x1017 | Float32 BE | Fluid conductivity ratio |
| 4120-4121 | 0x1018-0x1019 | Int32 BE | Forward totalizer (integer part) |
| 4122-4123 | 0x101A-0x101B | Float32 BE | Forward totalizer (decimal part) |
| 4124-4125 | 0x101C-0x101D | Int32 BE | Reverse totalizer (integer part) |
| 4126-4127 | 0x101E-0x101F | Float32 BE | Reverse totalizer (decimal part) |
| 4128 | 0x1020 | Uint16 | Flow rate unit code |
| 4129 | 0x1021 | Uint16 | Totalizer unit code |
| 4130 | 0x1022 | Uint16 | High alarm status (0=none, 1=active) |
| 4131 | 0x1023 | Uint16 | Low alarm status (0=none, 1=active) |
| 4132 | 0x1024 | Uint16 | Empty pipe alarm (0=none, 1=active) |
| 4133 | 0x1025 | Uint16 | System alarm (0=none, 1=active) |

### Flow Rate Unit Codes

| Code | Unit | Code | Unit | Code | Unit | Code | Unit |
|:-----|:-----|:-----|:-----|:-----|:-----|:-----|:-----|
| 0 | L/s | 3 | m³/s | 6 | T/s | 9 | GPS |
| 1 | L/min | 4 | m³/min | 7 | T/min | 10 | GPM |
| 2 | L/h | 5 | m³/h | 8 | T/h | 11 | GPH |

### Totalizer Unit Codes

| Code | 0 | 1 | 2 | 3 |
|:-----|:--|:--|:--|:--|
| Unit | L | m³ | T | USG |

## 6. Reading Data

### Read Instantaneous Flow

Read 2 registers from 0x1010 (device address 0x01):

```
Request:  01 04 10 10 00 02 74 CE
Response: 01 04 04 [4 bytes float] [CRC]
```

Assemble bytes as big-endian IEEE-754 float32: bytes[0-1] = high word (register 0x1010), bytes[2-3] = low word (register 0x1011).

### Read Instantaneous Velocity

```
Request:  01 04 10 12 00 02 D5 0E
Response: 01 04 04 [4 bytes float] [CRC]
```

### Read Forward Totalizer

Integer part (from 0x1018) + decimal part (from 0x101A). Combine for full 9-digit totalizer value.

```
Request (integer):  01 04 10 18 00 02 F5 0C
Request (decimal):  01 04 10 1A 00 02 54 CC
```

## 7. Address Configuration

Address and baud rate are set via the transmitter front-panel menu. The address range is 1-99. The default address is 1.

## 8. Outputs

### 4-20mA Current Output

- Range: 4mA (zero flow) to 20mA (full scale)
- Max load: 750Ω
- Also supports 2-wire (loop-powered) mode

### Frequency / Pulse Output

- Frequency range: 1-5000Hz (proportional to flow percentage)
- Pulse equivalent: 0.001-1.000 m³/pulse or L/pulse
- Opto-isolated: max 36VDC, 250mA

### Alarm Outputs

- ALMH / ALM1: activates when flow exceeds high setpoint
- ALML / ALM2: activates when flow drops below low setpoint
- Opto-isolated: max 36VDC, 250mA

## 9. Installation Notes

**Placement**

- Upstream straight run: 15D minimum
- Downstream straight run: 10D minimum
- Mount at 3 or 9 o'clock position (horizontal pipes) to keep electrodes away from sediment and air
- Pipe must remain completely filled during measurement
- Avoid installation near motors, transformers, or variable-frequency drives

**Hot-Tap Procedure**

- Weld the saddle and ball valve to the pipe before insertion
- Close ball valve; drill and deburr the tapping hole
- Insert probe to the correct depth (DN/2 for DN ≤400; DN/4 for DN >400)
- Open ball valve slowly; tighten the compression seal
- No flow interruption required during installation or removal

**Grounding**

The transmitter housing must be earthed with a minimum 1.6mm² copper conductor. Earth resistance to ground must be below 10Ω. Use the sensor flange and grounding ring for earth continuity.

## Ordering Information

| Part number | Description |
|:------------|:------------|
| AGRINOVO-EMF-200 | Insertion Electromagnetic Flow Meter |

## Revision History

| Rev | Date | Changes |
|:----|:-----|:--------|
| 1.0 | June 2026 | Initial release |
| 1.1 | August 2026 | Layout revision |
| 1.2 | October 2026 | New layout |

## Contact

Agrinovo, https://agrinovo.io/products, contact@agrinovo.io, +972 54 688 8148 (direct / WhatsApp).