# AGRINOVO-FSL-100: Digital Corrosion Rate Electrode Sensor (LPR / EIS)

Agrinovo technical datasheet, revision 1.2 (October 2026).
PDF version: https://agrinovo.io/datasheets/sensors/AGRINOVO-FSL-100_Datasheet.pdf

## 1. Overview

The AGRINOVO-FSL-100 is a smart corrosion rate electrode that combines Linear Polarization Resistance (LPR) and Electrochemical Impedance Spectroscopy (EIS) techniques. It measures both pitting corrosion and average corrosion rate in real time, with dual output via RS485 Modbus-RTU and 4 to 20mA. Built with 316L stainless steel and IP68 protection, it is designed for harsh industrial and environmental monitoring applications.

### Key Features

- LPR + EIS combined measurement
- Range: 0 to 0.25 / 0 to 0.5 / 0 to 1 / 0 to 5 mm/a
- Resolution: 0.0001 mm/a
- Dual output: RS485 + 4 to 20mA
- 316L stainless steel, IP68
- Wide supply: 12-24 VDC, <0.2W
- Low drift: ≤0.3% FS/24h
- Anti-polarization technology

### Applications

- Industrial cooling water corrosion monitoring
- Wastewater treatment pipeline assessment
- Environmental corrosion monitoring
- Process water quality control
- Infrastructure integrity monitoring

## 2. Specifications

| Parameter | Specification |
|:----------|:--------------|
| **Measurement Principle** | LPR + EIS |
| **Range** | 0 to 0.25 / 0 to 0.5 / 0 to 1 / 0 to 5 mm/a (configurable) |
| **Resolution** | 0.0001 mm/a |
| **Repeatability** | ±0.001 mm/a |
| **Response Time** | 50s |
| **Drift** | ≤0.3% FS / 24h |
| **Output** | RS485 Modbus-RTU + 4 to 20mA |
| **Supply Voltage** | 12-24 VDC |
| **Power Consumption** | <0.2W |
| **Operating Temp** | 0 to 75°C |
| **Protection** | IP68 |
| **Housing Material** | 316L Stainless Steel |
| **Mounting Thread** | 1" NPT |
| **Cable Length** | 5m (standard) |

## 3. Wiring

### RS485 Mode (4 wires)

| Wire Color | Function | Description |
|:-----------|:---------|:------------|
| **Red** | V+ | Power Supply (12-24V DC) |
| **Blue** | GND | Power Ground |
| **Yellow** | RS485-A | Data+ |
| **Green** | RS485-B | Data− |

### 4 to 20mA Mode (3 wires)

| Wire Color | Function | Description |
|:-----------|:---------|:------------|
| **Red** | V+ | Power Supply (12-24V DC) |
| **Blue** | GND | Power Ground |
| **Black** | 4 to 20mA+ | Analog Current Output |

### RS485 + 4 to 20mA Mode (5 wires)

Use all five wires: Red (V+), Blue (GND), Yellow (485-A), Green (485-B), Black (4 to 20mA+).

## 4. Communication Settings

| Parameter | Value |
|:----------|:------|
| **Protocol** | Modbus-RTU |
| **Baud Rate** | 9600 bps (configurable: 2400/4800/9600/19200/38400/43000) |
| **Data Bits** | 8 |
| **Parity** | None |
| **Stop Bits** | 1 |
| **Default Address** | 0x09 |

**Note:** For communication distances exceeding 100m, reduce baud rate to 4800 or 2400 for stability.

## 5. Register Map

All measurement values are IEEE-754 float32, each occupying 2 registers. Read via function 0x03.

### Measurement Registers (Function 0x03  -  Read Only)

| Address | PLC Address | Description | Range | Data Type |
|:--------|:------------|:------------|:------|:----------|
| 0x0000 to 0x0001 | 40001 | Corrosion Rate | 0 to 5 mm/a | Float32 |
| 0x0002 to 0x0003 | 40003 | Polarization Voltage | −1250 to 1250 mV | Float32 |
| 0x0004 to 0x0005 | 40005 | Reserved | - | Float32 |
| 0x0006 to 0x0007 | 40007 | Current Step | - | Float32 |
| 0x0010 to 0x0011 | 40017 | Temperature Correction | - | Float32 |
| 0x0012 to 0x0013 | 40019 | Baud Rate | - | Float32 |
| 0x0014 to 0x0015 | 40021 | Slave Address | - | Float32 |
| 0x0016 to 0x0017 | 40023 | Filter Time (seconds) | - | Float32 |
| 0x0018 to 0x0019 | 40025 | Electrode Sensitivity | - | Float32 |
| 0x001A to 0x001B | 40027 | Measurement Time | - | Float32 |
| 0x001C to 0x001D | 40029 | Model | - | Float32 |
| 0x001E - 0x001F | 40031 | Software Version | - | Float32 |
| 0x0020 to 0x0021 | 40033 | 4 to 20mA High Point | - | Float32 |

### Configuration Registers (Read/Write)

| Address | PLC Address | Description | Data Type | Values |
|:--------|:------------|:------------|:----------|:-------|
| 0x0008 to 0x0009 | 40009 | Corrosion Coefficient | Float32 (0x10) | R/W |
| 0x0012 | 40019 | Set Baud Rate | Signed (0x06) | 2400/4800/9600/19200/38400/43000 |
| 0x0014 | 40021 | Set Slave Address | Signed (0x06) | 1 to 254 |
| 0x0016 | 40023 | Trigger Measurement | Signed (0x06) | Write 1 (wait 0 to 3s) |
| 0x0018 | 40025 | Set Filter Seconds | Signed (0x06) | Seconds |
| 0x001A | 40027 | Set Compensation Mode | Signed (0x06) | 0=Auto, 1=Manual |
| 0x0032 | 40051 | Float Byte Order | Signed (0x06) | 0=Normal, 1=Reversed |
| 0x0064 | 40101 | Restore Defaults | Signed (0x06) | Write 1 |
| 0x270F | 41000 | Restore Baud & Address | Signed (0x06) | Write 1 |

## 6. Reading Data

### Read corrosion rate, polarization voltage, and reserved value

Read 6 registers from 0x0000 (3 float32 values):

```
Request:  09 03 00 00 00 06 C4 80
Response: 09 03 0C [Float1: 4 bytes] [Float2: 4 bytes] [Float3: 4 bytes] [CRC]
```

**Decoding:**

| Registers | Description | Example |
|:----------|:------------|:--------|
| 0x0000 to 0x0001 | Corrosion Rate | **0.1280 mm/a** |
| 0x0002 to 0x0003 | Polarization Voltage | **xxx.x mV** |
| 0x0004 to 0x0005 | Reserved | - |

**Float byte order:** Default is normal order. Can be switched to reversed via register 0x0032.

## 7. Address Configuration

### Change Slave Address (0x09 → 0x02)

Write to register 0x0014 (40021) using function 0x06:

```
09 06 00 14 00 02 49 47
```

### Change Baud Rate (9600 → 19200)

Write to register 0x0012 (40019) using function 0x06:

```
09 06 00 12 4B 00 1E 77
```

Supported baud rates: 2400, 4800, 9600, 19200, 38400, 43000.

### Restore Baud Rate and Address to Defaults

Write 1 to register 0x270F (41000):

```
09 06 27 0F 00 01 73 F5
```

## 8. Calibration

Calibration is performed via the companion PC software (USB-485 adapter required).

### Software Calibration Features

- Set calibration standard value
- Adjust corrosion coefficient (K factor) via register 0x0008
- Set low-range K and high-range K coefficients
- Configure 4 to 20mA high point and correction coefficient

### Trigger Immediate Measurement

Write 1 to register 0x0016 (40023). Result available after 0 to 3 seconds:

```
09 06 00 16 00 01 A8 86
```

## 9. Factory Reset

### Restore All Defaults

Write 1 to register 0x0064 (40101):

```
09 06 00 64 00 01 08 9D
```

### Restore Only Baud Rate and Address

Write 1 to register 0x270F (41000):

```
09 06 27 0F 00 01 73 F5
```

## 10. Installation Notes

**Placement**

- Mount using 1" NPT pipe thread
- Install both electrode tips into the sensor body
- Water flow direction should be perpendicular to the gap between the two electrodes
- Ensure electrodes are fully submerged

**Maintenance**

- Soak electrode in water for 15 minutes before first use
- Clean electrode tips before measurement; remove oil with cloth, detergent, or dilute acid
- For carbon steel electrodes, inspect regularly and replace if heavily corroded
- Store in dry environment when not in use

## Ordering Information

| Part number | Description |
|:------------|:------------|
| AGRINOVO-FSL-100 | Digital Corrosion Rate Electrode Sensor (LPR / EIS) |